YCFP7 Strip-Shaped Hot Aerosol Fire Extinguisher | CNC | CNC Electric
products
YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)

Picture
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)
  • YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)

YCFP7 Hot Aerosol Fire Extinguisher Device(strip-shaped)

The YCFP7 Strip-Shaped Hot Aerosol Fire Extinguishing Device is designed for electrical cabinets and relatively large enclosed equipment compartments. Its elongated stainless-steel housing with red coating makes efficient use of narrow internal mounting spaces.

With six agent quantities from 50 g to 300 g, the series protects enclosed volumes of up to 3 m³ and supports both electrical and thermal activation.

Contact Us

Product Details

Working Principle

When a fire occurs, the fire extinguishing device is activated after receiving an electrical triggering signal or when an open flame ignites the thermal-sensitive wire. The electrical initiator or thermal initiator activates the aerosol-generating agent inside the device. Through an oxidation reduction reaction, the aerosol-generating agent releases heat, causing the composite cooling agent to decompose, thereby achieving coordinated fire suppression by both the aerosol-generating agent and the composite cooling agent.

Product Advantages

Made of stainless steel with red coating; pressureless storage, maintenance-free, high fire extinguishing efficiency, safe and reliable, environmentally friendly; strong environmental adaptability, suitable for ambient temperatures from –50°C to +90°C (short-term up to +125°C); equipped with 3M adhesive on the back for direct attachment inside enclosures, and can also be reinforced with screws.

Application Scenarios

Communication cabinets, power distribution cabinets, battery swap cabinets, motor vehicle engine compartments, compressors, and other relatively enclosed small spaces for early-stage fire suppression.
 

Unpacking Inspection

1. During unpacking inspection, check the delivered documents and accessories according to the Packing List.
If any items are missing or damaged, please contact the supplier immediately.
2. Check whether the device is provided with a Product Certificate of Conformity. If the certificate is missing, please contact the distributor as soon as possible.
Do not use the device without this certificate.
 

Installation and Commissioning

Installation Requirements for the Thermal Aerosol Fire Extinguishing Device:
1. The installation position is not restricted by height.
2. No other objects are allowed to cover the product.
3. The device should not be installed near air inlets, air outlets, doors, windows, or other openings.
4. The device should not be installed in locations exposed to rain, water splashing, or flooding.
 

Technical date

Product Model YCFP7-D0.05G/SQR YCFP7-D01GSQR YCFP7-D0.15GSQR YCFP7-D02GSQR   YCFP7-D025GSQR YCFP7-D03G/SQR
Extinguishing Agent Quantity 50g 100g 150g 200g 250g 300g
Protected Volume ≤0.5m³ ≤1m³  ≤1.5m³ ≤2m³   ≤2.5m³ ≤3m³
Dimensions 90*66*46  255*66*46 255*115*46
Extinguishing Density 100g~130/m³ 100g~130/m³ 100g~130/m³ 100g~130/m³ 100g~130/m³   100g~130/m³
OperatingAmbient Temperature -45℃~+90℃ -45℃~+90℃ -45℃~+90℃ -45℃~+90℃ -45℃~+90℃   -45℃~+90℃
Ambient Relative Humidity ≤95%RH ≤95%RH  ≤95%RH ≤95%RH   ≤95%RH ≤95%RH
Activation Method Electrical activation or thermal activation
Activation Current ≥380mA
Safety Current ≤150mA
Activation Voltage 24V(DC)
Service Life 10 years
Oxidizing Agent and Content Sr(NO₃)₃60%/KNO₂20%
Nozzle Thermal Spacing 0.3m≤75℃,0.12m≤200℃,0.05m≤400℃
Applicable Standard EN 15276-1:2019,EN 15276-2:2019,

Usage and Operation Precautions

1. Before installation, carefully read the User Manual of the thermal aerosol fire extinguishing device. If there are any questions, please consult the company’s technical personnel in time.
2. Installation and commissioning of the thermal aerosol fire extinguishing device must be carried out by professionally trained personnel.
3. After installation, the thermal aerosol fire extinguishing device must not be moved arbitrarily.
4. In case of fire, on-site personnel must evacuate immediately and close doors and windows as much as possible during evacuation.
5. After the expiration of the service life, the user shall contact the supplier for replacement and recycling.
6. After discharge, if the device needs to be removed within a short period, high-temperature protective gloves must be worn to avoid burns.
7. Disassembly is strictly prohibited, whether the device is within or beyond its service life, to prevent accidents.
8.When installed inside a high-voltage electrical cabinet, the thermal aerosol fire extinguishing device must maintain a safe clearance from live electrical parts.