General
YCB7LE-63Y series integrated residual current operated circuit breaker is mainly used in AC50/60Hz rated voltage 230V rated current up to 63A lines,as a load line for leakage (electricshock),overload and short circuit protection.It can also be used for infrequent connection,disconnection,and switching.
Standard:|EC/EN 61009-1
General
YC9VA voltageand current display relay is a microprocessor-based voltagemonitoring devicefor single-phase AC networksto protectelectrical equipment from surge voltage.The deviceanalyzes the main voltage and displays its curent valueon a digitalindicator Load is switched by electromagnetic relay.The user canset the current voltage value and delaytime throughthe buttonThe value isstored in non-volatile memory.Aluminum wires and copper wires can be used forconnection.
The YCB9ZF – 100AP is an advanced smart IoT circuit breaker engineered to meet the modern demands of energy management and circuit protection. With a focus on safety, efficiency, and connectivity, it stands out as a reliable solution for various applications.
The YCB9ZF – 100W is a smart circuit breaker. It offers IoT – enabled remote control via multiple protocols and voice assistants.
It has 10,000 + mechanical cycles, IP20 rating, and wide – temperature operation. Easy to install on DIN rails, it comes with safety features. IEC 60898 – 1 certified, suitable for various applications.
General
1.Protection against the effects of sinusoidal alternating earth fault currents
2.Protection against indirectcontacts and additional protection against direct contacts
3.Protection against fire hazard caused byinsulation faults
4.Controlling and Switching
5.Used in residential building,non-residential building,energy sources,industry and infrastructure
Voltage and current display relay is a microprocessor-based voltage monitoring device for sinale-phase AC networks to protect electrical equipment from surge voltage. The device analyzes the main voltage and displays its curent value on a digital indicator. Load is switched by electromagnetic relay. The user can set the current voltage value and delay time through the button.The value is stored in non-volatile memory. Aluminum wires and copper wires can be used for connection.
1.Overload protection
2.Short circuit protection
3.Controlling
4.Used in residential building,non-residential building,energy source industry and infrastructure.
General
YCB7RL-100 series electromagnetic residual current operated circuit breaker (RCCB) is mainlysuitable for AC distribution networks with a rated working voltage of 230V or 400V at 50Hzand a rated current of 63A.Used for indirect contact protection of people,and can also beused to prevent fire hazards caused by insulation damage to circuits and equipment,resulting in ground fault currents.
General
YCH7-125 series isolating switch is suitable in the resistive circuit of AC 50/60HZ,rated voltage 230/400V,rated current up to 125A.
It’s used primarily for circuit’s turning on or off in non-loadedsituation.And it functions on connection and isolation between lines and power,especially suitable to isolate power effectively and prevent circuit breaker from closing acidentally when maintain the circuit in order to ensure the safe operation of maintainer.
Standard:IEC600947-3
General
1.Protection against the effects of sinusoidal alternating earth fault currents
2.Protection against indirect contacts and additional protection against direct contacts
3.Protection against fire hazard caused byinsulation faults
4.Controlling and Switching
5.Used in residential building,non-residential building,energysources,industryand infrastructure
YCB6-63 miniature circuit breaker(circuit breaker) is applicable to the circuit with AC50Hz/60Hz, rated voltage of no more than 400V, rated current up to 63 A for overload protection and short circuit protection. This product can be applied to various places such as industrial, commercial, tall buildings,and residential houses.
Standard: IEC60898-1