YCQ6 Automatic Transfer Switch ATS is used for automatic or manual changeover between main and standby power sources in low-voltage distribution systems. It supports AC400V, 50/60Hz systems and covers rated current from 16A to 3200A.
It is suitable for utility-generator or main-standby power transfer in hospitals, banks, high-rise buildings, industrial facilities, and other critical power supply applications. The product supports automatic control, remote electric operation, emergency manual operation, and emergency disconnection, meeting the requirements of reliable and safe power transfer.
Standard: IEC 60947-6-1
Contact Us
| Frame class | 100 | 160 | 250 | 630 | 1600 | 3200 | ||||||||||||||||
| Rated current In(A) | 16 | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 |
| Rated insulation voltage(Ui) | 500V | 800V | ||||||||||||||||||||
| Rated concussion withstand voltage(Uimp) |
6KV | 8KV | ||||||||||||||||||||
| Rated working voltage(Ue) | AC400V | |||||||||||||||||||||
| Using category | AC-33iB | |||||||||||||||||||||
| Rated short-circuit connection capacity |
8KA | 17KA | 67KA | |||||||||||||||||||
| Rated short-time withstand current(Icw) |
5KA/30ms | 10KA/60ms | 12.6KA/60ms | |||||||||||||||||||
| Transfer time I-ll or II-I | ≤3s | ≤5s | ||||||||||||||||||||
| Control voltage | AC230V | |||||||||||||||||||||
| Rated frequency | Start | 20W | 325W | 355W | 400W | 440W | 600W | |||||||||||||||
| Normal | 62W | 74W | 90W | 98W | 120W | |||||||||||||||||
Common questions about YCQ6 automatic transfer switch ATS selection, application, and operation.
YCQ6 automatic transfer switch is used to switch between the main power supply and standby power supply automatically or manually. It is suitable for critical power distribution systems where power continuity is important, such as hospitals, banks, high-rise buildings, industrial facilities, and generator backup systems.
The YCQ6 automatic transfer switch covers a rated current range from 16A to 3200A, making it suitable for different levels of low-voltage power distribution systems.
YCQ6 ATS is designed for AC400V systems with a rated frequency of 50/60Hz, which makes it suitable for common low-voltage distribution applications.
Yes. YCQ6 automatic transfer switch can be used for changeover between utility power and generator power. When the main power supply fails, the ATS can transfer the load to the standby power source to help maintain power continuity.
YCQ6 automatic transfer switch is designed according to IEC 60947-6-1, which is a relevant standard for low-voltage transfer switching equipment.
YCQ6 ATS is suitable for power supply systems in hospitals, banks, high-rise buildings, commercial buildings, factories, data centers, and other locations where reliable backup power transfer is required.
Yes. YCQ6 ATS supports multiple operation modes, including automatic control, electric remote control, emergency manual operation, and emergency disconnection under automatic state.
When selecting a YCQ6 ATS, key factors include rated current, rated voltage, number of poles, power source type, load characteristics, installation method, control requirements, and whether the system uses utility-generator or utility-utility power changeover.
The transfer time of YCQ6 ATS depends on the frame size. According to the product technical data, the transfer time is generally within ≤3s or ≤5s depending on the model range.
You can contact CNC Electric directly through the official website inquiry form, WhatsApp, or email. For project purchasing, OEM/ODM cooperation, or bulk orders, it is recommended to provide the required current rating, voltage, pole configuration, application scenario, and quantity for accurate model selection and quotation.