Home >  Products > Power Transmission & Distribution Equipments > Oil-immersed Tranformer (up to 35kV) > SBH15 Series 10kV Immersed

SBH15 Series 10kV Immersed


  • Product description

    1.Amorphous core distribution transformers. Core is its amorphous alloy with soft magnetic material's characteristics can further reduce the distribution system for loss and reduce air pollution. This new transformer transformer compared with the conventional silicon steel, cut 80% of the no-load loss is efficient and energysaving effect. Superscript reached the world's advanced level.
    2.Amorphous alloy is a new energy-saving materials, iron, boron and other elements of solid materials used in producing rapid condensation urgent Arts, to their physical properties and performance of non-crystal metal atoms arranged disorderly, it is totally different from the crystal structure with silicon steel was more conducive to magnetization and magnetic. This new materials for transformer cores. Operating pressure changes at 100-120 times per second magnetized by the magnetic and said to be relatively easy thus greatly reducing the core of the no-load loss, but also reduce emissions if used in oil-immersed transformers CO, SO.NOX and other harmful gases, and has been called the 20th century's"green materials."
    3.SBH15-based amorphous alloy core distribution transformer products that both single or three-phase five-volume box cores. Core Molding frame clamping plates, foil around for the type of low voltage windings so low loss, the short circuit capacity. advanced structural reasonable overall performance indicators have reached the world's advanced level.


    Implementation of the standards

    1.GB1094.1-1996 power transformers part 1, general provisions;
    2.GB1094.2-1996 power transformers, part 2 wenzhou;
    3.Part 3 GB1094.3-2003 power transformer insulation, insulation and the outer insulating air space experience;
    4.GB1094.5-2003 power transformer short -circuit under Part 5;
    5.JB/T10318-2002 amorphous alloy core distribution transformers immersed technical parameters and requirements;



    Models and meaning












  • Main technical parameters

    Type
    Rated capacity
    (kV A)
    No-loadloss
    (W)
    No-load current
    (%)
    Load loss 75℃ (W)
    Short circuit
    impedance
    (%)
    Noise level
    (db)
    (Y)
    (D)
    S(B)H15-50/10
    50
    43
    1.3
    870
    910
    4
    50
    S(B)H15-100/10
    100
    75
    1.0
    1500
    1580
    4
    52
    S(B)H15-160/10
    160
    100
    0.7
    2200
    2310
    4
    54
    S(B)H15-200/10
    200
    120
    0.7
    2600
    2730
    4
    56
    S(B)H15-250/10
    250
    140
    0.7
    3050
    3200
    4
    56
    S(B)H15-315/10
    315
    170
    0.5
    3650
    3830
    4
    58
    S(B)H15-400/10
    400
    200
    0.5
    4300
    4520
    4
    58
    S(B)H15-500/10
    500
    240
    0.5
    5150
    5410
    4
    60
    S(B)H15-630/10
    630
    320
    0.3
    6200
    6200
    4.5
    60
    S(B)H15-800/10
    800
    380
    0.3
    7500
    7500
    4.5
    62
    S(B)H15-1000/10
    1000
    450
    0.3
    10300
    10300
    4.5
    62
    S(B)H15-1250/10
    1250
    530
    0.2
    12000
    12000
    4.5
    65
    S(B)H15-1600/10
    1600
    630
    0.2
    14500
    14500
    4.5
    65
    S(B)H15-2000/10
    2000
    750
    0.2
    17400
    17400
    5
    65
    S(B)H15-2500/10
    2500
    900
    0.2
    20200
    20200
    5
    67


    Type
    Rated capacity
    (kV A)
    The dimension (mm)
    L×B×H
    Gauge (mm)
    Oil weight (kg)
    Total weight (kg)
    Transverse
    Longitudinal
    S(B)H15-50/10
    50
    950×620×1040
    660
    580
    160
    680
    S(B)H15-100/10
    100
    1060×770×1070
    820
    720
    180
    880
    S(B)H15-160/10
    160
    1100×830×1200
    820
    760
    200
    1100
    S(B)H15-200/10
    200
    1150×850×1250
    820
    760
    220
    1190
    S(B)H15-250/10
    250
    1260×870×1200
    820
    760
    250
    1350
    S(B)H15-315/10
    315
    1350×910×1250
    820
    840
    280
    1600
    S(B)H15-400/10
    400
    1450×920×1300
    820
    840
    330
    1900
    S(B)H15-500/10
    500
    1410×960×1260
    820
    840
    350
    2100
    S(B)H15-630/10
    630
    1900×980×1450
    1070
    840
    420
    2460
    S(B)H15-800/10
    800
    1980×1000×1350
    1070
    900
    500
    2900
    S(B)H15-1000/10
    1000
    2060×1160×1310
    1070
    1020
    550
    3300
    S(B)H15-1250/10
    1250
    2160×1190×1450
    1070
    1020
    680
    4000
    S(B)H15-1600/10
    1600
    2250×1380×1600
    1070
    1220
    750
    4600
    S(B)H15-2000/10
    2000
    2410×1460×1620
    1070
    1220
    840
    5300
    S(B)H15-2500/10
    2500
    2520×1520×1680
    1070
    1020
    950
    6200
  • Outline and size